Rehoboth Marine Equipment Repair L.L.C provides vessel switchboard troubleshooting for marine electrical systems, attending onboard at Fujairah anchorage, the Port of Fujairah and other UAE ports from our workshop in the Al Hayl Industrial Area. We investigate earth faults, nuisance tripping, blackouts, synchronising and load sharing problems, protection relay mis-operation, and heat damage on main and emergency switchboards.

Switchboard faults are rarely where the alarm says they are. Our engineers work from the ship's electrical drawings and measured values rather than replacing components on suspicion, and hand over the cause and the test readings in writing so the finding survives the next inspection.

Marine engineer carrying out vessel switchboard troubleshooting onboard at Fujairah port

Our Switchboard Fault Diagnosis Checklist

This is the sequence our engineers follow onboard - the same checklist a superintendent can hand to the ship's staff before we arrive.

  1. 01

    Alarm history and load condition

    We take the alarm printout and establish exactly what the plant was doing when the fault appeared - load change, generator start, heavy consumer cut in, or at rest.

  2. 02

    Safe isolation and visual inspection

    The affected section is isolated and locked off, then checked for discoloured or slack connections, tracking marks, moisture ingress and salt or oil contamination inside the panel.

  3. 03

    Thermal and connection checks

    Busbar and terminal connections are checked for heating and re-torqued where required. Loose terminations are a common root cause behind repeat trips.

  4. 04

    Earth fault localisation

    Insulation resistance is measured and the distribution split feeder by feeder to isolate the faulty circuit, rather than condemning the whole board or leaving the earth lamp indication unresolved.

  5. 05

    Protection and breaker testing

    Overcurrent, reverse power, under-voltage and preference trip settings are verified against the drawings, and breaker mechanisms, contacts and closing coils tested.

  6. 06

    Synchronising and load sharing

    Governor and AVR response, droop settings, synchroscope and auto-synchronising function and kW/kVAr sharing between generators are checked under load.

  7. 07

    Generator side verification

    If the fault sits on the machine, insulation resistance, polarisation index, AVR, rotating diodes and slip rings are tested - and a rewind quoted from our Fujairah workshop if the winding has failed.

  8. 08

    Repair, controlled re-energising and report

    After repair the section is re-energised in a controlled sequence, load tested, and the cause and readings issued to the vessel in a written report.

Common Switchboard Symptoms and Their Usual Causes

What the fault looks like from the control room, and where it usually turns out to be.

SymptomWhere it usually pointsWhat we do first
Earth fault lamps indicating on one phaseMoisture ingress, damaged cable or a failing consumer on one feederInsulation resistance measurement and feeder-by-feeder splitting to localise
Breaker trips on load change onlyProtection setting mismatch, loose termination, or a partially failed contactVerify settings against drawings, thermal check and re-torque of terminations
Blackout on generator changeoverPreference trip, synchronising or governor and AVR responseCheck synchronising gear, droop settings and load sharing under controlled test
Uneven kW or kVAr sharing between generatorsGovernor droop and AVR cross-current compensationMeasure and adjust droop and excitation response on load
Burning smell or discolouration inside the panelLoose or overheating connection, tracking across insulationIsolate immediately, inspect, clean and re-terminate; test insulation before re-energising
Repeated generator trips with no board faultMachine side - insulation failure, AVR, diodes or slip ringsInsulation and polarisation index testing, AVR and excitation checks, rewind advice if needed

Blackout, Earth Fault or Nuisance Tripping?

Call our marine electrical team with the alarm history and load condition. We attend at Fujairah anchorage and across UAE ports with test equipment and the drawings-first approach.

Frequently Asked Questions

Can you localise an earth fault without shutting down the vessel?

In most cases yes. The distribution is split feeder by feeder under controlled conditions with the ship's staff, so the faulty circuit is identified with minimum disruption.

Do you test protection relays and breakers as well as fault find?

Yes. Overcurrent, reverse power, under-voltage and preference trip settings are verified against the ship's drawings and breaker mechanisms and contacts tested.

What should the ship prepare before you attend?

The alarm printout, the electrical drawings, generator maker and rating, and a clear account of the load condition when the fault appeared.

If the fault is in the generator winding, can you rewind it?

Yes. Machines that need rewinding come to our rewinding bay in the Al Hayl Industrial Area, Fujairah and are returned tested, impregnated and dynamically balanced.